ISO9001
ISO13485
ISO14001
Certified |
|
AQUACOUNTER
AQ-300 Karl Fischer Coulometric Titrator |
AQ-300 |
Looking for a reliable, easy-to-use coulometric Karl Fischer titrator on a tight budget?
Then look no further than the Aquacounter AQ-300.
With state-of-the-art performance features, like a fritless cell option, the AQ-300 offers the same fast and accurate results you've come to expect from other AQUACOUNTER products. |
 |
Features
|
COMPACT !
All components are integrated in a small footprint of 31 cm (W) x 27 cm (D).
Saves valuable bench space.
SIMPLE !
No need to determine the KF reagent titre. Just flip the POWER on, the titrator will be
ready to run within 30 minutes. Simple as 1,2,3 Go!
POWERFUL !
4 user defined methods can be stored in memory and easily recalled according to
samples.
Up to 20 results can be stored with statistics calculation.
Detection limit goes down to several ppm.
SATISFACTION !
Equipped with two RS-232C ports for balance and computer connection.
Standard package includes AQUANet data download software, instruction movie,
application guidebook and more
|
Standard Specifications
|
| Item |
Specifications |
| Titration method |
Coulometric titration process. |
| Electrolytic control method |
Constant current electrolysis, intermittent electrolysis in the vicinity of the end point only. |
| End point detection |
AC polarization potential difference detection. |
| Titration control method |
| Automatic endpoint stop system: |
| (1) |
Wait-time (INTERVAL) controlled; duration from 1 - 99 sec. |
| (2) |
Titration time (T-TIMER) controlled; duration from 1 - 99 min. |
|
| Measuring range |
10 g H2O - 99 mg H2O |
| Automatic background compensation range |
0 - 50 g H2O/min. |
| Accuracy |
Within CV of 0.3 %, When water - methanol (1mg H2O/mL) 1g is measured 10 times. |
| Required measuring time |
FAST: 1.2 mg H2O/min. (20 g H2O/sec.), SLOW: 0.6 mg H 2 O/min. (10 g H2O/sec.) |
| Titration cell capacity |
150 mL |
| Display screen |
2-lines by 16digits with backlit LCD |
| Display unit |
g H2O, ppm, % |
| Calculation function |
Concentration calculation, Statistics calculation |
| File function |
4 files for titration parameters |
| Memory data capacity |
20 data |
| Printers |
Optional thermal printer; PR-2000T3,
Optional dot impact printer; PR-302B(CBM-910-40PF) |
| Printout Contents |
Date, Sample number, Measurement value( g H2O), Sample quantity, Moisture content, Mean value, Standard deviation, CV, Moisture quantity-time curve, Other preset titration parameters. |
| External input/output |
| RS-232C; 2 ports |
|
Port 1 (BALANCE): Connection to electronic balance.
Port 2 (HOST): Connection to external computer. |
|
| Power supply ; Power consumption |
AC 100 - 240 V, 50/60 Hz & 100 VA |
| Dimensions & Weight |
W 310 mm x D 270 mm x H 300 mm ;
Approx, 5 kg |
|
Options
|
| Thermal Printer PR-2000T3 |
Paper width:80mm |
| Dot Impact Printer PR-302B |
Paper width:58mm |
Solid Evaporator EV-2000
(For solid/powder samples)
|
EV-2000 vaporizes water of a solid / powder sample by heating. Ideal for "the solid / powder sample that it is difficult to measure it directly".
*Operation key-pad is necessary for use. |
Oil Evaporator EV-2000L (For Oil, Paint and other liquid samples)
|
Utilizing azeotropic distillation, EV-2000L separates moisture from sample matrices and introduces into the titration cell.
Interference form sample matrix is minimized and titration time is shortened. |
Generally a company name printing in this catalogue and a product name are a
trademark of the company or registered trademarks.
The product color may vary from the actual product due to printing qualities.
Appearance, specification, etc. are subject to change for improvement without prior
notice
[Note]
For safe and appropriate use, please be sure to read the "Instruction Manual" before using the product.
|