Automated Solid Evaporator
SE-320

Continuous automatic measurement system
for solid/powder samples for 20 samples
Equipped with automatic reagent
exchange function
Create a system by combining it with a KF Titrator.
A series of operations such as sample container transfer, heating, and measurement are performed automatically.
*Since sales availability, products and services vary by country and region, please contact your Hitachi High-Tech Analysis contact, the exclusive distributor, for specific requests and questions.
Product features
1.Automatic measurement
Multiple samples can be measured automatically for efficient moisture measurement.
2. Heating temperature (room temperature to 300℃)
The sample heating temperature can be set arbitrarily from room temperature to 300°C.
3.Measurement condition file
There are 50 measurement condition files, and optimal temperature settings can be registered for each sample.
4.Temperature increase can be set for each sample
Up to 3 steps of temperature increase can be set for each sample.
5.Easy-to-handle sample bottles
The container is straight from the bottom to the mouth, making it easy to take out the dissolved sample.
6.Automatic reagent exchange function is standard
The reagent replacement can be set by the number of measurements to automatically drain and replace the generator electrolyte.
Specification
For KF titrator, please refer to the specifications of the KF titrator to be combined.
Moisture vaporization method | Ventilation heating vaporization method |
---|---|
Sample container | Hard glass Bottle, aluminum foil packing, PTFE lid |
Number of sample containers | 20 samples |
Sample amount (volume) | About 10 mL or less |
Carrier gas | N2 gas (or dry air from an optional dry air pump) Flow rate : 30 to 300 mL / min (depending on setting) |
Reagent exchange | Automatic exchange by setting the number of measurements |
Carrier gas Desiccant | Molecular sieves |
Heater/Temperature control | Band heater, PID control method |
Temperature range | From room temperature to 300 ℃, Up to 3 levels can be set |
End position setting | When the stop pin is set to the end position or no container is detected |
Post-measurement procedures | End buzzer |
Power supply | AC 100 - 240 V 50/60 Hz About 150 VA A power cable is not included in this product. (*1) |
Dimensions / Weight | Sample changer: 350(W)x 510(D) x 390(H) mm / approx. 19kg Valve box: 275(W) x 440(D) x 280(H) mm / approx. 9kg |
*1: The power inlet of this product complies with IEC60320 C14.
Please prepare a power cable that can be connected to this power inlet.